Doepfer MCV24 Midi CV/Gate/Sync Interface (device no longe Manual de usuario Pagina 22

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 25
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 21
TRIGGER LEVEL ON
Sets the output level of the trigger on signal, referenced as a percentage of maximum (10.6v for outputs
13 ~ 24). So 50% would generate a 5.3V trigger. For V-Trig applications (positive gate like Doepfer A-100
and most others) use high percentage for Trigger Level on, and for S-Trig applications (like Moog) use a
Trigger On Level of 0%.
TRIGGER LEVEL OFF
Sets the output level of the trigger off signal, referenced as a percentage of maximum (10.6v for outputs
13 ~ 24). So 50% would generate a 5.3V trigger. For V-Trig applications (positive gate like Doepfer A-100
and most others) use a Trigger Level off of 0%, and for S-Trig applications (like Moog) use a Trigger Off
Level of 100% (or suitable high level).
GLOBAL SYNC PARAMETER
The Global Sync Parameter is where control over the system clock and sync parameters are set.
CLOCK TIME
This sets the MIDI clock division ratio, a normal setting of 1 passes the MIDI clock unprocessed,
whilst a setting of 3, divides the clock by 3 (1/96 becomes 1/32). Range is 1 ~ 255.
Trigger:Output01
LevelOn V %:100
Trigger:Output01
LevelOff V %:000
<-----F>:Output01
Global Sync Par.
Sync-Clock
Clock Time:001
Vista de pagina 21
1 2 ... 17 18 19 20 21 22 23 24 25

Comentarios a estos manuales

Sin comentarios