DOEPFER A-100CGK Guía de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
If the jumper is removed the gate output has S-Trig or switching trigger function, i.e.
the gate terminal is connected to GND (instead of a voltage output). This function
have most of the Moog devices. But from our experience they work also with +5V
gate voltage and inverted gate polarity so that it is not necessary to change the
jumper setting (without obligation).
If the device connected to the gate output uses voltage gate but does not trigger
probably the level of the gate voltage is not sufficient. In this case the position of the
jumper has to be changed as mentioned above and a power supply with sufficient
voltage (e.g. 12V) has to be used. Typical examples are Roland synthesizers.
The factory setting is positive polarity and +5V gate voltage (internal jumper).
HOLD
This configuration menu is not used so far.
To leave the configuration mode and enter the normal operation mode the power
supply has to be removed and then connected again after a few seconds without
pressing one of the buttons. Then the normal operation mode is called up and the
previously adjusted parameters in the configuration mode are valid (i.e. number of
octaves of the keyboard, transpose type and gate polarity).
Extent of delivery
The A-100CGK delivery contains the following parts:
1. Ready built version with metal case and 4 octaves keyboard
A-100CGK with black metal case and 4 octaves keyboard
Power Supply (230V mains voltage, European type mains plug, output voltage
range 7...12V, current min. 100 mA) included only for shipments within Germany,
for shipments outside Germany please contact your local representative or dealer
Four A-100 patch cables, length 80 cm
This A-100CGK user's guide
2. OEM version
A-100CGK electronic kit (two pc boards with ribbon cable to connect the boards)
Power Supply (230V mains voltage, European type mains plug, output voltage
range 7...12V, current min. 100 mA) included only for shipments within Germany,
for shipments outside Germany please contact your local representative or dealer
Four A-100 patch cables, length 80 cm
This A-100CGK user's guide
The keyboard, connection cable between keyboard and A-100CGK are not included
with the OEM version of A-100CGK. These parts have to be ordered separately !
Please use the link accessories and spare parts of the product overview page. Prices
can be found in the price list.
Vista de pagina 10
1 2 ... 6 7 8 9 10 11 12

Comentarios a estos manuales

Sin comentarios